Exoskeleton Increases Walking Efficiency
May 2015

It’s taken millions of years for humans to perfect the art of walking. But research results, “Reducing the energy cost of human walking using an unpowered exoskeleton,” published recently in the journal Nature, show that humans can actually get better ‘gas mileage’ using an unpowered exoskeleton to modify the structure of their ankles. The exoskeleton device puts an extra spring in each human step, reducing metabolic energy consumption by 7 percent below walking in normal athletic shoes.

Graduate student Audrey Westbrook looks on as Dr. Bruce Wiggin uses exoskeleton devices to walk on a treadmill. The devices increase walking efficiency by 7 percent in able-bodied adults. Photo courtesy of Marc Hall, NC State University.

The finding may potentially benefit both able-bodied people who are frequently on their feet, such as the military, factory workers or athletic baby-boomers, for example, as well as those who have been victims of stroke, sports injury, accidents or other gait impairments.

To gain an advantage over nature, North Carolina State University (NC State) and Carnegie Mellon University researchers tested the efficacy of a lightweight lower-leg device that uses a spring and clutch system working in tandem with calf muscles and the Achilles’ tendon while people walk. The streamlined, carbon-fiber device weighs about as much as a normal loafer – around 500 grams, or a bit more than a pound – and is not motorized, so it requires no energy from batteries or other external fuel sources.

“The unpowered exoskeleton is like a catapult. It has a spring that mimics the action of your Achilles’ tendon, and works in parallel with your calf muscles to reduce the load placed upon them,” said Dr. Gregory Sawicki, a biomedical engineer and locomotion physiologist in the joint NC State/ University of North Carolina-Chapel Hill Department of Biomedical Engineering who co-authored the paper. “The clutch is essential to engage the spring only while the foot is on the ground, allowing it to store and then release elastic energy. Later it automatically disengages to allow free motion while the foot is in the air.”

The study participants – nine able-bodied adults – strapped the exoskeleton devices on both legs and walked at a normal speed on a treadmill after completing some practice training. The same subjects also walked without exoskeletons for a baseline comparison.

The researchers tested exoskeletons with springs that varied in stiffness. The spring that provided the most benefit was moderately stiff. Walking with exoskeletons with springs that were too stiff or too compliant resulted in normal or higher-than-normal energy costs for participants.

“A 7 percent reduction in energy cost is like taking off a 10-pound backpack, which is significant,” Dr. Sawicki said. “Though it’s surprising that we were able to achieve this advantage over a system strongly shaped by evolution, this study shows that there’s still a lot to learn about human biomechanics and a seemingly simple behavior like walking.”

Along with Steven Collins at Carnegie Melon University, Dr. Bruce Wiggin, a former NC State graduate student, co-authored the paper. Funding for the research was provided by grants from the NC State Faculty Research and Professional Development Fund; the NC State Chancellors Innovation Fund; from the U.S.-Israel Binational Science Foundation; and from the National Institute of Nursing Research of the National Institutes of Health. It was also supported by a grant from the National Science Foundation.

Article reprinted from materials provided by North Carolina State University. ##